Helium vs Dye — A Leak Sensitivity Comparison

Dye ingress and helium leak detection were tested on identical defective vials. Helium quantified leaks down to single-digit microns. Dye missed most of them entirely. For high-value biologics, vaccines, and any product where a sub-micron breach matters, dye testing gives false confidence.

This head-to-head study compared traditional dye ingress against helium leak detection — the most sensitive CCIT method available. Helium detected leaks far smaller than dye could reveal, down to the single-digit micron range, with quantitative leak-rate data. The practical lesson: if your product is a high-value biologic, a vaccine, or anything where a sub-micron breach matters, dye testing gives false confidence. 
 
Technology: Helium Leak Detection →PTI Helium
Out of 50 vials with engineered defects from 2 to 50 μm: dye detected 14 (28%). Helium detected 49 (98%) and quantified the leak rate of each.